2 - 36
Macro type to specify network ••••••••••••••••••••••••••••[OUT_ENQ] command of [SYS]
The addresses n+0 and n+1 are fixed for 0 and 2.
Specify n+2 [System code] to 1: NET/10 2: NET II(/B)
Enter “0” to n+3 [Network No.] when n+2 [System code] indicates “2”, and “the number to be
accessed” to n+3 [Network No.] when n+2 [System code] indicates “1”.
No macros can include this command except Open Macro. Communication error will occur due to the
execution of the netware change when this command is used in other kinds of macros.
Refer to the “UGseries Manual <Function> (FEH376)” for further information on Macro.
Also refer to MITSUBISHI's manual for network registration.
See MITSUBISHI’s manual for details on the NET II(/B) data link system and the NET/10 network system.
Available Memory
See P2-16, “A/QnA series link units” and P2-22, “A/QnA series CPU port” for available memory of the PLC to
be accessed.
Note that CPU No. should be set on the UG00S-CW.
Wiring
See the wiring diagrams on P2-16,17, “1 MITSUBISHI PLC • 1.”
12 MITSUBISHI PLC 6
F1 Memory
n+0 0 (fixed)
n+1 Specify network: 2 (fixed)
n+2 System code
n+3 Network No.